Sierra 10: The World’s Most Compact Multidirectional Infrastructure

Sierra 10 Multidirectional system with IEC sockets

The most compact device of its kind, delivering up to 6 kW of multidirectional power in a single 1U rack unit.

Features decentralized, independent logic with no master-slave relationship; systems remain fully functional in fallback mode without a controller.

Configurable for single-phase or three-phase architectures, with dedicated 120VAC and 230VAC versions available for global deployment.

Internal DC energy buffering ensures zero voltage interruption to the load when transitioning between grid and battery sources.

Seamlessly bridges 50Hz and 60Hz standards, allowing the same hardware to adapt to different international grid requirements.

Designed for rapid field scaling and maintenance, allowing modules to be added or replaced in live systems without downtime.

From high-density edge subracks to global modular plants, these configurations are engineered to SECURE mixed AC and DC infrastructure with zero single points of failure.

Sierra 10 shelf

Available in hard-wired or front-mounted IEC socket variants, these subracks significantly reduce installation complexity. They manage redundant internal communication buses and provide fallback logic that secures the load during controller maintenance, making them ideal for mission-critical edge deployments.

Sierra 10 3-shelf system with Inview S

Managed by Inview X or S controllers, these plants provide deep telemetry and automated battery management. The multidirectional 3-port logic allows for unique configurations, such as 3-phase grid input feeding protected single-phase loads, ensuring absolute power resilience for commercial and industrial sites.

The hardware and intelligent control layers that drive the bidirectional and decentralized logic of Sierra 10 Multidirectional Systems.

Sierra-10-module
Inview-S-Slot
  • Connectivity: Supports industry-standard protocols including Modbus RS485/TCP, SNMP v1-v3, and HTTP/HTTPS for seamless BMS integration.
  • Battery Management: Includes built-in algorithms for battery health monitoring and control to ensure maximum backup autonomy.
  • Cybersecurity: Features advanced security protocols and encryption (SSL/TLS) to protect critical power infrastructure from unauthorized access.
MBB

Consult with our engineering team to define modular 3-port requirements using the most compact multidirectional technology available. We provide technical expertise in configuring decentralized, high-availability architectures for 48VDC environments, ensuring absolute load continuity in DC, UPS, or energy storage modes with optional grid-interactive functionality.